http://www.rollershutters.com.au/ "Keeping you cool, keeping you
warm, keeping you safe"


Aluminium Security Roller Shutter


Bushfire Rated to BAL 40


Tested in compliance with AS 1530.8.1-2007


Slat

Roller Shutter components:
Aluminium Head Box
Aluminium Slat profile
Aluminium Guides and Bottom Bar

Security Roller Shutter
The Security Roller Shutter displays superior strength over other standard slat profiles buy greatly reduces bending and flexing.
This strength offers increased security and performance.

The Security Roller Shutter has an Extruded Aluminium Slat (AE401)that has been developed as a premium product for security conscious buyers, or wherever superior strength is required.

Back in 2002 OZRoll had approached the CSIRO to determine the benefits of our window roller shutters when subjected to excessive heat throughout a simulated bushfire attack.

Fire test 1

The end result was that the shutter was proven to withstand a maximum radiant heat flux of 29kw/m2 and had still remained
operable.

This test was for the AR400 slat used in the manufacture of the Domestic Roller Shutter.
There have also been factual accounts where the OZRoll shutters have been credited with saving homes from burning to the ground when other surrounding properties were not so fortunate.

Fire 2

After the most recent fires in Victoria there were changes made to local council regulations that required new dwellings to comply with specific ratings, in particular within high risk areas.
With this in mind OZRoll again carried out further testing with the CSIRO however on this occasion it was decided to test for a higher rating using our AE401 extruded aluminium shutter which is used in the manufacture of the Security Roller Shutter.


Fire 3

The test was completed In November 2010 and the conclusion for this test was that the OZRoll window shutter was again proven to withstand the impact of a simulated bushfire attack, however this time with a maximum radiant heat exposure of 40kw/m2.

After 60 minutes of severe testing there was no ignition or flaming observed and we are now pleased to confirm that the

OZROLL AE401 shutter passed to the level of BAL 40.


CSIRO – Bushfire Simulation Testing on OZRoll® Window Shutters.

It is common knowledge that hot or burning embers entering the home is a major factor for the ignition of the building itself. The above test report proves conclusively that the home stands a better chance in case of bushfire if fitted with OZRoll® roller shutters.

Report Number: FSZ 1444
Job Number: SZ3303
Date of Issue: 5th November 2010

CSIRO Report

Colour Range

Security Roller Shutter Colour Options. 8 box colours and 8 slat colours offer multiple combinations.